Part Number : MS25273ASGD1
NSN : 5945-00-803-0785 (5945008030785)
Item Name : Relay Electromagnet
Manufacturer : Leach Corp
CAGE Code : 35318
NIIN : 008030785
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-00-803-0785 Item Description: Relay Electromagnet | 5945 | 008030785 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Ms25273asgd1 | 1 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
AAJD | THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
AAJF | THREAD DIRECTION | RIGHT-HAND SINGLE MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 1.531 INCHES MAXIMUM |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.687 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 2.218 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 1.100 INCHES MAXIMUM |
ADTV | CASE MATERIAL | METAL |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AKDX | WINDING QUANTITY | 1 |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APCN | COIL QUANTITY | 1 |
APNQ | ARC QUENCHING METHOD | AIR |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD SINGLE MOUNTING FACILITY |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CBME | III CUBIC MEASURE | 3.735 CUBIC INCHES |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 200.0 MILLIAMPERES DC SINGLE WINDING |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD AND 10.0 AMPERES DC RESISTIVE LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC LAMP LOAD AND 2.0 AMPERES DC LAMP LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 4.0 AMPERES AC MOTOR LOAD AND 4.0 AMPERES DC MOTOR LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 6.0 AMPERES AC INDUCTIVE LOAD AND 6.0 AMPERES DC INDUCTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
TTQY | TERMINAL TYPE AND QUANTITY | 8 WIRE HOOK ALL FUNCTIONS |
ZZZK | SPECIFICATION/STANDARD DATA | 96906-MS25273 GOVERNMENT STANDARD |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.187 INCHES NOMINAL SINGLE MOUNTING FACILITY |
APNP | DUTY TYPE | CONTINUOUS |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE MOUNTING FACILITY |
CRXH | TIME DELAY | 0.02 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTIN |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
Low Price Warrantied inventory at competitive prices
Find it fast Search the world's largest inventory of electronic components by manufacturer, category or part number
Quality guaranteed We sell only warrantied and traceable parts
Get it fast All inventory ready to ship from our sellers
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
Remember Us the Next Time If You are Looking for Aircraft Parts.
Request for Quote